e-shop for radio tubes and rare electronic components pentod.com
Language: EN
Currency: BGN
  • BGN
  • EUR
Welcome to our store!

Dropdown Categories

Dropdown Categories

TRANSFORMERS TRANSFORMERS

«1»

Products

Transformer matching TM5-19 USSR

Transformer matching  TM5 19 USSR
 
Military performance
 
Technical data :
Magnetic wire - permalloy
Operating frequency 100-10000 Hz
Rated power- 0,1VA
Resonant frequency  not more than 1000 Hz
Test voltage - 100 V
Maximum primary winding voltage - 12X2 V
Input impedance  -  564 Ω
Output impedance 35 Ω
Inductance of the primary winding 0,45H
Operating temperature ...... -60...+125 °C;
Made in the USSR 
Price: 9.60лв.
Quantity:

Transformer matching T0,5-26 USSR

Transformer matching T0,5 26 USSR
 
Military performance
 
Technical data :
Magnetic wire - permalloy
Operating frequency 100-10000 Hz
Rated power- 0,5VA
Resonant frequency  not more than 1000 Hz
Test voltage - 100 V
Maximum primary winding voltage - 42 V
Input impedance  -  2256 Ω
Output impedance 70,5 Ω
Inductance of the primary winding - 1,8H
Operating temperature ...... -60...+125 °C;
Made in the USSR 
Price: 12.00лв.
Quantity:

Transformer matching T0,7-29 USSR

Transformer matching T0,7 29 USSR
 
Military performance
 
Technical data :
Magnetic wire - permalloy
Operating frequency 100-10000 Hz
Rated power- 0,7VA
Resonant frequency  not more than 1000 Hz
Test voltage - 100 V
Maximum primary winding voltage - 42 V
Input impedance  -  2256 Ω
Output impedance 564 Ω
Inductance of the primary winding - 1,8H
Operating temperature ...... -60...+125 °C;
Made in the USSR 
Price: 12.00лв.
Quantity:

Transformer matching TOT-110 USSR

Transformer matching TOT 110 USSR
 
Military performance
 
Technical data :
Magnetic wire - permalloy
Operating frequency 300-10000 Hz
Rated power- 2,5 VA
Resonant frequency  not more than 1000 Hz
Test voltage - 500 V
Maximum primary winding voltage - 12X2 V
Input impedance  -  150/330/590 Ω
Output impedance 256/360/512 Ω
Inductance of the primary winding - 0.22 H
Inductance of the secondary winding  - 0.012H
Operating temperature ...... -60...+125 °C;
Made in the USSR 
Price: 9.60лв.
Quantity:

Transformer matching TOT-111 USSR

Transformer matching TOT 111 USSR
 
Military performance
 
Technical data :
Magnetic wire - permalloy
Operating frequency 300-10000 Hz
Rated power- 2,5 VA
Resonant frequency  not more than 1000 Hz
Test voltage - 500 V
Maximum primary winding voltage - 12X2 V
Input impedance  -  150/330/590 Ω
Output impedance 720/1020/1140 Ω
Inductance of the primary winding - 0.22 H
Inductance of the secondary winding  - 0.012H
Operating temperature ...... -60...+125 °C;
Made in the USSR 
Price: 9.60лв.
Quantity:

Transformer matching TOT-133 USSR

Transformer matching TOT 133 USSR
 
Military performance
 
Technical data :
Magnetic wire - permalloy
Operating frequency 300-10000 Hz
Rated power- 2,5 VA
Resonant frequency  not more than 1000 Hz
Test voltage - 500 V
Maximum primary winding voltage - 16X2 V
Input impedance  -  106/240/425 Ω
Output impedance 90/126/180 Ω
Inductance of the primary winding - 0.6 H
Inductance of the secondary winding  - 0.034H
Operating temperature ...... -60...+125 °C;
Made in the USSR 
Price: 12.00лв.
Quantity:

Transformer matching TOT-34 USSR

Transformer matching TOT 34 USSR
 
Military performance
 
Technical data :
Magnetic wire - permalloy
Operating frequency 300-10000 Hz
Rated power- 0,1VA
Resonant frequency  not more than 1000 Hz
Test voltage - 500 V
Maximum primary winding voltage - 12X2 V
Input impedance  -  5600/22400 Ω
Output impedance 500/2000 Ω
Inductance of the primary winding 7,8H
Inductance of the secondary winding  - 0,5H
Operating temperature ...... -60...+125 °C;
Made in the USSR 
Price: 9.60лв.
Quantity:
«1» Page 1 of 1