«1
Products
Transformer matching TM5-19 USSR
Transformer matching TM5 19 USSR
Military performance ♦
Technical data :
Magnetic wire - permalloy
Operating frequency 100-10000 Hz
Rated power- 0,1VA
Resonant frequency not more than 1000 Hz
Test voltage - 100 V
Maximum primary winding voltage - 12X2 V
Input impedance - 564 Ω
Output impedance - 35 Ω
Inductance of the primary winding - 0,45H
Operating temperature ...... -60...+125 °C;
Made in the USSR
|
Price:
9.60лв.
|
|
Transformer matching T0,5-26 USSR
Transformer matching T0,5 26 USSR
Military performance ♦
Technical data :
Magnetic wire - permalloy
Operating frequency 100-10000 Hz
Rated power- 0,5VA
Resonant frequency not more than 1000 Hz
Test voltage - 100 V
Maximum primary winding voltage - 42 V
Input impedance - 2256 Ω
Output impedance - 70,5 Ω
Inductance of the primary winding - 1,8H
Operating temperature ...... -60...+125 °C;
Made in the USSR
|
Price:
12.00лв.
|
|
Transformer matching T0,7-29 USSR
Transformer matching T0,7 29 USSR
Military performance ♦
Technical data :
Magnetic wire - permalloy
Operating frequency 100-10000 Hz
Rated power- 0,7VA
Resonant frequency not more than 1000 Hz
Test voltage - 100 V
Maximum primary winding voltage - 42 V
Input impedance - 2256 Ω
Output impedance - 564 Ω
Inductance of the primary winding - 1,8H
Operating temperature ...... -60...+125 °C;
Made in the USSR
|
Price:
12.00лв.
|
|
Transformer matching TOT-110 USSR
Transformer matching TOT 110 USSR
Military performance ♦
Technical data :
Magnetic wire - permalloy
Operating frequency 300-10000 Hz
Rated power- 2,5 VA
Resonant frequency not more than 1000 Hz
Test voltage - 500 V
Maximum primary winding voltage - 12X2 V
Input impedance - 150/330/590 Ω
Output impedance - 256/360/512 Ω
Inductance of the primary winding - 0.22 H
Inductance of the secondary winding - 0.012H
Operating temperature ...... -60...+125 °C;
Made in the USSR
|
Price:
9.60лв.
|
|
Transformer matching TOT-111 USSR
Transformer matching TOT 111 USSR
Military performance ♦
Technical data :
Magnetic wire - permalloy
Operating frequency 300-10000 Hz
Rated power- 2,5 VA
Resonant frequency not more than 1000 Hz
Test voltage - 500 V
Maximum primary winding voltage - 12X2 V
Input impedance - 150/330/590 Ω
Output impedance - 720/1020/1140 Ω
Inductance of the primary winding - 0.22 H
Inductance of the secondary winding - 0.012H
Operating temperature ...... -60...+125 °C;
Made in the USSR
|
Price:
9.60лв.
|
|
Transformer matching TOT-133 USSR
Transformer matching TOT 133 USSR
Military performance ♦
Technical data :
Magnetic wire - permalloy
Operating frequency 300-10000 Hz
Rated power- 2,5 VA
Resonant frequency not more than 1000 Hz
Test voltage - 500 V
Maximum primary winding voltage - 16X2 V
Input impedance - 106/240/425 Ω
Output impedance - 90/126/180 Ω
Inductance of the primary winding - 0.6 H
Inductance of the secondary winding - 0.034H
Operating temperature ...... -60...+125 °C;
Made in the USSR
|
Price:
12.00лв.
|
|
Transformer matching TOT-34 USSR
Transformer matching TOT 34 USSR
Military performance ♦
Technical data :
Magnetic wire - permalloy
Operating frequency 300-10000 Hz
Rated power- 0,1VA
Resonant frequency not more than 1000 Hz
Test voltage - 500 V
Maximum primary winding voltage - 12X2 V
Input impedance - 5600/22400 Ω
Output impedance - 500/2000 Ω
Inductance of the primary winding - 7,8H
Inductance of the secondary winding - 0,5H
Operating temperature ...... -60...+125 °C;
Made in the USSR
|
Price:
9.60лв.
|
|
«1